HARMONIC FILTERING
Three phase
5th harmonic absorption filter
400V
50 Hz
Reference |
Rating
kVA (*) |
IN (A) |
I5(A) |
F5T |
10 |
10 |
14,5 |
6 |
" |
12,5 |
12,5 |
18 |
7 |
" |
16 |
16 |
23 |
9 |
" |
20 |
20 |
29 |
12 |
" |
25 |
25 |
36 |
14 |
" |
31,5 |
31,5 |
46 |
18 |
" |
40 |
40 |
58 |
23 |
" |
50 |
50 |
72 |
29 |
" |
63 |
63 |
91 |
36 |
" |
80 |
80 |
116 |
46 |
" |
100 |
100 |
144 |
58 |
(*)
Rating of frequency converter
Dimensions
and Weights
Reference |
Rating
kVA (*) |
Dimensions
mm |
Weight
kg |
Figure |
A |
B |
C |
F5T |
10 |
10 |
380 |
480 |
515 |
37 |
1 |
" |
12,5 |
12,5 |
380 |
480 |
515 |
39 |
1 |
" |
16 |
16 |
380 |
610 |
670 |
71 |
1 |
" |
20 |
20 |
380 |
610 |
670 |
81 |
1 |
" |
25 |
25 |
380 |
610 |
670 |
100 |
1 |
" |
31,5 |
31,5 |
380 |
610 |
670 |
111 |
1 |
" |
40 |
40 |
670 |
810 |
986 |
195 |
2 |
" |
50 |
50 |
670 |
810 |
986 |
218 |
2 |
" |
63 |
63 |
670 |
810 |
986 |
267 |
2 |
" |
80 |
80 |
670 |
810 |
986 |
316 |
2 |
" |
100 |
100 |
670 |
810 |
986 |
331 |
2 |
(*)Rating
of frequency converters
Technical
Characteristics
Frequency |
50
Hz |
Voltage |
400V |
Test
voltage |
3
kV (1 min, 50 Hz) |
Protection
degree |
IP-23 |
Maximum
admissible distortion in load |
I3:0,04�I1 |
I11:0,12�I1 |
I5:0,45�I1 |
I13:0,05�I1 |
I7:0,20�I1 |
I17:0,05�I1 |
Designed
for three phase frequency converters |
Ambient
temperature |
ta=40�C |
Standards |
IEEE
519
IEC/EN/UNE-EN 60439
IEC/EN 60289
IEC/EN/UNE-EN 60831 CE |
Three phase
5th and 7th harmonic absorption filter
400V 50
Hz
Reference |
Rating
kVA (*) |
IN (A) |
I5(A) |
I7(A) |
F57T |
12,5 |
12,5 |
18 |
7 |
3 |
" |
16 |
16 |
23 |
9 |
4 |
" |
20 |
20 |
29 |
12 |
5 |
" |
25 |
25 |
36 |
14 |
6 |
" |
31,5 |
31,5 |
46 |
18 |
8 |
" |
40 |
40 |
58 |
23 |
10 |
" |
50 |
50 |
72 |
29 |
13 |
" |
63 |
63 |
91 |
36 |
16 |
" |
80 |
80 |
116 |
46 |
20 |
" |
100 |
100 |
144 |
58 |
25 |
(*)
Rating of frequency converters
Dimensions
and Weights
Reference |
Rating
kVA (*) |
Dimensions
mm |
Weight
kg |
Figure |
A |
B |
C |
F57T |
12,5 |
12,5 |
380 |
610 |
670 |
73 |
1 |
" |
16 |
16 |
380 |
610 |
670 |
79 |
1 |
" |
20 |
20 |
380 |
610 |
670 |
93 |
1 |
" |
25 |
25 |
670 |
810 |
986 |
175 |
2 |
" |
31,5 |
31,5 |
670 |
810 |
986 |
183 |
2 |
" |
40 |
40 |
670 |
810 |
986 |
232 |
2 |
" |
50 |
50 |
670 |
810 |
986 |
252 |
2 |
" |
63 |
63 |
670 |
810 |
986 |
284 |
2 |
" |
80 |
80 |
670 |
810 |
986 |
328 |
2 |
" |
100 |
100 |
670 |
810 |
986 |
419 |
2 |
(*)Rating
of Frequency converters
Technical
Characteristics
Frequency |
50
Hz |
Voltage |
400V |
Test
voltage |
3
kV (1 min, 50 Hz) |
Protection
degree |
IP-23 |
Maximum
admissible distortion in load |
I3:0,04�I1 |
I11:0,12�I1 |
I5:0,45�I1 |
I13:0,05�I1 |
I7:0,20�I1 |
I17:0,05�I1 |
Designed
for three phase frequency converters |
Ambient
temperature |
ta=40�C |
Standards |
IEEE
519
IEC/EN/UNE-EN 60439
IEC/EN 60289
IEC/EN/UNE-EN 60831 CE |
|